Table 31 iSCSI or iSCSI/FCoE module log messages (continued)
iSCSI processor (adapter) failed to provide a
heartbeat for x seconds.
ErroriSCSI#%d: QLReadyTimer: Adapter
missed heartbeat for 0x%x
seconds
74659
iSCSI processor failed to complete an abort request.ErroriSCSI#%d: QLReadyTimer: Abort
pTpb=%p failed, DrvCount
0x%x
74660
Driver timed out an iSCSI processor operation and
is aborting the operation.
ErroriSCSI#%d: QLTimer: Abort pTpb=%p,
Type %x, Timeout 0x%x
DrvCount 0x%x, DdbIndex 0x%x
74661
Driver timed out an iSCSI processor mailbox
command.
ErroriSCSI#%d: QLReadyTimer: MBOX_CMD
%04x %04x %04x %04x %04x
%04x %04x %04x timed out
74663
Driver timed out while attempting to reconnect with
the iSNS.
ErroriSCSI#%d: QLReadyTimer:
QLiSNSReenable failed.
74665
iSCSI processor was restarted.ErroriSCSI#%d: QLProcessSystemError:
Restart RISC
74705
iSCSI processor rejected the firmware initialize
command.
ErroriSCSI#%d: QLInitializeFW:
MBOX_CMD_INITIALIZE_FIRMWARE
74746
failed %04x %04x %04x %04x
%04x %04x
Driver’s initiator database is full. The driver is
capable of storing 1024 iSCSI initiators in its
ErroriSCSI#%d: QLUpdateInitiatorData:
No more room in Initiator
Database.
74784
database. Use the CLI or GUI to remove
unwanted/unused iSCSI initiators.
Driver’s target database is full. Use the CLI or GUI
to remove unwanted/unused iSCSI targets.
ErroriSCSI#%d: QLSetTargetData: No
more room in Target
Database.
74800
TCP retry for a frame failed on the connection
ddbIndex. Tpb contains the frame memory
address.
ErroriSCSI#%d: ql_process_error:
OB_TCP_IOCB_RSP_W returned
DdbInx 0x%x pTpb %p
75008
Restart iSCSI processor (RISC).InfoiSCSI#%d: QLDisable: Restart RISC86347
EEPROM updated, restart iSCSI processor (RISC).InfoiSCSI#%d: QLEnable: Restart RISC
to update EEPROM
86349
Link up reported by iSCSI processor for GE1 or GE
2.
InfoiSCSI#%d: QLIsrDecodeMailbox:
Link up
86874
iSCSI controller reported a link speed/configuration
of 100 Mb full-duplex (FDX).
InfoiSCSI#%d: QLGetFwStateCallback:
link 100Mb FDX
87346
iSCSI controller reported a link speed/configuration
of 1000 Mb FDX.
InfoiSCSI#%d: QLGetFwStateCallback:
link 1000Mb FDX
87348
iSCSI controller reported an invalid link speed.InfoiSCSI#%d: QLGetFwStateCallback:
Invalid link speed 0x%x
87350
FC1 processor SRAM test failed.FatalFC#%d: qlutm_init: Diagnostic
failed, port 1 invalid SRAM
102419
FC1 processor power-on self-test (POST) failed.FatalFC#%d: qlutm_init: Diagnostic
failed, port 1 POST failed
102420
FC2 processor SRAM test failed.FatalFC#%d: qlutm_init: Diagnostic
failed, port 2 invalid SRAM
102421
FC2 processor POST failed.FatalFC#%d: qlutm_init: Diagnostic
failed, port 2 POST failed
102422
273