Running a firmware verification scan
Prerequisites
Configure iLO Settings privilege
An iLO license that supports this feature is installed.
Procedure
1. Navigate to the Administration page, and then click the Firmware Verification tab.
2. Click Run Scan.
When a firmware verification scan is in progress, you cannot install firmware updates or upload
firmware to the iLO Repository.
The scan results are displayed at the top of the page.
Viewing firmware health status
Prerequisites
An iLO license that supports this feature is installed.
Procedure
Navigate to the Administration page, and then click the Firmware Verification tab.
Firmware health status details
Firmware Name
The name of the installed firmware.
Firmware Version
The firmware version.
Health
The firmware health status.
State
The firmware status. The possible values follow:
Enabled—The firmware is verified and enabled.
Scanning—A firmware verification scan is in progress or is about to start.
Flashing—A firmware update is in progress.
Failed/Offline—The firmware could not be verified and was not repaired.
Running a firmware verification scan 221