Viewing general system information
Viewing health summary information
The Health Summary page displays the status of monitored subsystems and devices. Depending on the
server configuration, the information on this page varies.
If the server is powered off, the system health information on this page is current as of the last power off.
Health information is updated only when the server is powered on and POST is complete.
Procedure
Click System Information in the navigation tree.
Redundancy status
Redundancy status is displayed for the following:
Fan Redundancy
Power Status
Subsystem and device status
Summarized status information is displayed for the following:
Agentless Management Service
BIOS/Hardware Health
Fans
Memory
Network
Power Supplies (nonblade servers only)
Processors
Storage
Temperatures
Smart Storage Battery Status (supported servers only)
Subsystem and device status values
The Health Summary page uses the following status values:
Redundant—There is a backup component for the device or subsystem.
OK—The device or subsystem is working correctly.
Not Redundant—There is no backup component for the device or subsystem.