Loading...
Fan degraded
Fan repaired
Fan redundancy lost
Fans redundant
Power supply inserted
Power supply removed
Power supply failure
Power supplies redundancy lost
Power supplies redundant
Temperature over threshold
Temperature normal
Automatic shutdown started
Automatic shutdown canceled
Drive failure
Viewing the IML
Procedure
1. Click Information in the navigation tree, and then click the Integrated Management Log tab.
2. Optional: Use the IML sort, search, and filter features to customize the log view.
The total number of recorded events is always displayed above the filter icon. When filters are applied,
the number of events that meet the filter criteria is displayed below the filter icon.
3. Optional: To view the event details pane, click an event.
IML details
The first column on the left side of the web interface displays an active check box next to each event
with Critical or Caution status. Use this check box to select an event to mark as repaired.
ID—The event ID number. Events are numbered in the order in which they are generated.
By default, the IML is sorted by the ID, with the most recent event at the top. A factory reset will reset
the counter.
Severity—The importance of the detected event.
Class—Identifies the type of event that occurred, for example, UEFI, environment, or system revision.
Description—The description identifies the component and detailed characteristics of the recorded
event.
If the iLO firmware is rolled back, the description UNKNOWN EVENT TYPE might be displayed for
events recorded by the newer firmware. You can resolve this issue by updating the firmware to the
latest supported version, or by clearing the log.