For example, if one side is autoselecting the connection, the other side must use the same setting.
Unable to return to iLO login page after iLO reset
Symptom
The iLO login page will not open after an iLO reset.
Action
Clear the browser cache and restart the browser.
An iLO connection error occurs after an iLO firmware update
Symptom
You cannot connect to iLO after updating the firmware by using the web interface.
Action
Clear the browser cache and try again.
Unable to connect to iLO processor through NIC
Symptom
The iLO processor is inaccessible through the NIC.
Action
• Use the ROM-based system utility to confirm that the NIC is enabled, and to verify the assigned IP
address and subnet mask.
For more information, see the ROM-based system utility documentation.
• Ping the IP address of the NIC from a separate network workstation.
• Attempt to connect with a browser by entering the IP address of the NIC as the URL. You can see the
iLO login page from this address.
• Reset iLO. If a network connection is established, you might have to wait up to 90 seconds for the
DHCP server request.
Unable to log in to iLO after installing iLO certificate
Symptom
iLO is inaccessible after the iLO self-signed certificate is installed in the browser certificate store.
Cause
When you reset iLO to the factory default settings or change the iLO hostname, a new self-signed
certificate is generated. In some browsers, if the self-signed certificate is installed permanently, you might
not be able to log in to iLO after a new self-signed certificate is generated.
Unable to return to iLO login page after iLO reset 367