115
Step
Command
Remarks
4.
Load the upgrade
images
as main
startup software
images on
subordinate
members.
• Use .bin files:
issu load file { boot filename |
system filename | feature
filename&<1-30> }
* slot
slot-number
• Use an .ipe file:
issu load file ipe ipe-filename
slot slot-number&<1-9>
Specify the member ID of a subordinate
member for the slot-number argument.
5. P
erform a
master/subordinate
switchover.
issu run switchover
N/A
6. (Optional.) Accept
the upgrade and
delete the
automatic rollback
timer.
issu accept
N/A
7.
Upgrade the
remaining
members to
complete the ISSU.
issu commit slot
slot-number
IMPORTANT:
After executing the command for one
member, you must wait for the member
to restart and join the IRF fabric before
you execute the command for another
member.
Repeat the
issu commit
command to
upgrade the remaining members one by
one, including the original master.
To manually roll back to the original
software images d
uring this ISSU
process, use the
issu rollback
command.
For more information about rollback,
see
Fundamentals Command
Reference.
Performing an incompatible upgrade
Perform this task in user view.
Step
Command
Remarks
1. Load the upgrade
images
as main
startup software
images on
subordinate
members.
• Use .bin files:
issu load file { boot filename |
system filename | feature
filename&<1-30> }
* slot
slot-number&<1-9>
• Use an .ipe file:
issu load file ipe ipe-filename
slot slot-number&<1-9>
Specify the member ID of a subordinate
member for the slot-number argument.
As a best practice on a ring-topology
IRF fabric, specify half of the
subordinate members for this command
to reduce service downtime. Make sure
the specified subordinate members are
physically connected.
2. P
erform a
master/subordina
te switchover to
c
omplete the
ISSU process.
issu run switchover
To
roll back to the original software
images during this ISSU process, use
the
issu rollback
command.
This ISSU process
does not support
automatic rollback.
For more information about rollback,
see
Fundamentals Command
Reference.

Table of Contents

Other manuals for HPE FlexNetwork 5510 HI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork 5510 HI Series and is the answer not in the manual?

HPE FlexNetwork 5510 HI Series Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork 5510 HI Series
CategorySwitch
LanguageEnglish

Related product manuals