22
Step
Command
Remarks
6. Specify the
number of data
bits for each
character.
databits
{
5 | 6 | 7
|
8
}
The default is 8.
Configure this command depending the
character coding type. For example, set the
number of data bits to 7 for standard ASCII
characters.
Set the number of data bits to 8
for extended ASCII characters.
This command is not available in AUX line
class view.
7. Define a shortcut
key for
starting a
terminal session.
activation-key
character
By default, pressing
Enter
starts the terminal
session.
8.
Define a shortcut
key for terminating
tasks.
escape-key
{ character |
default
}
By default, pressing
Ctrl+C
terminates a
task.
9. Configure the flow
control mode.
flow-control
{
hardware
|
none
|
software
}
This command is not available in AUX line
class view.
By default, the flow control mode is
none
.
10. Specify the
terminal display
type.
terminal type
{
ansi | vt100
}
By default, the terminal display type is ANSI.
The device supports ANSI and VT100
terminal display types. As a best practice, set
the display type to VT100 on both the device
and the configuration terminal. If either side
uses the ANSI type, a display problem such
as cursor positioning error might occur when
a command line has more than 80
characters.
11. Set the maximum
number of lines to
be displayed on a
screen.
screen-length
screen-length
By default, a screen displays up to 24 lines.
A value of 0 disables
pausing between
screens of output.
12. Set the size of the
command history
buffer.
history-command max-size
value
By default, the buffer saves up to 10 history
commands.
13. Set the CLI
connection
idle-timeout timer.
idle-timeout
minutes
[
seconds
]
By default, the CLI connection idle-timeout
timer is 10 minutes.
If no interaction occurs between the device
and the user within the idle-timeout interval,
the system automatically terminates the user
connection on the user line.
If you set the timeout timer to 0, the
connection will not be aged out.
Logging in through Telnet
You can Telnet to the device to remotely manage the device, or use the device as a Telnet client to
Telnet to other devices to manage them.
By default, Telnet login is disabled on the device. To log in to the device through Telnet, you must
perform the following tasks:
•
Log in to the device through any other method.
•
Enable the Telnet server.
•
Configure Telnet login authentication on the device.

Table of Contents

Other manuals for HPE FlexNetwork 5510 HI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork 5510 HI Series and is the answer not in the manual?

HPE FlexNetwork 5510 HI Series Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork 5510 HI Series
CategorySwitch
LanguageEnglish

Related product manuals