146
• Critical alarm threshold—48
MB.
• Normal state threshold—128
MB.
3.
usage threshold.
memory-threshold usage [ slot
slot-number [ cpu cpu-number ] ]
memory-threshold
By default, the memory usage
threshold is 100%.
Configuring the temperature alarm thresholds
The device monitors its temperature through temperature sensors, based on the following
thresholds:
Low-temperature threshold.
High-temperature warning threshold.
High-temperature alarming threshold.
When the temperature drops below the low-temperature threshold or reaches the high-temperature
warning threshold, the device performs the following tasks:
Logs the event.
Sends a log message.
Sends a trap.
When the temperature reaches the high-temperature alarming threshold, the device performs the
following tasks:
Logs the event.
Sends log messages repeatedly.
Sets the LEDs on the device panel.
To configure the temperature alarm thresholds:
1. Enter system view.
system-view
N/A
2.
Configure the
temperature alarm
thresholds.
temperature-limit
slot
slot-number
hotspot
sensor-number lowlimit
warninglimit [ alarmlimit ]
To view the default settings, use the
undo
temperature-limit
command to
restore the defaults and then execute
the
display environment
command.
The high-temperature alarming
threshold must be higher than the
high-temperature warning threshold.
The high-temperature warning
threshold
low-temperature threshold.
Disabling all USB interfaces
You can use USB interfaces to upload or download files. By default, all USB interfaces are enabled.
You can disable USB interfaces as needed.
To disable all USB interfaces: