145
Table 14 Memory alarm notifications and memory alarm-removed notifications
Minor alarm notification
The amount of free memory
space decreases to or below the
minor alarm threshold for the first
time.
After generating and sending a minor alarm
notification, the system does not generate
and send any additional minor alarm
notifications until the
removed.
Severe alarm notification
The amount of free memory
space decreases to or below the
severe alarm threshold for the
first time.
After generating and sending a severe
alarm notification, the system does not
generate and send any additional severe
alarm notifications until the
alarm is removed.
Critical alarm notification
The amount of free memory
space decreases to or below the
critical alarm threshold for the
first time.
After generating and sending a critical
alarm notification, the system does not
generate and send any additional critical
alarm notifications until the
alarm is removed.
Critical alarm-removed
notification
The amount of free memory
space increases to or above the
severe alarm threshold.
N/A
Severe alarm-removed
notification
The amount of free memory
space increases to or above the
minor alarm threshold.
N/A
Minor alarm-removed
notification
The amount of free memory
space increases to or above the
normal state threshold.
N/A
Figure 48 Memory alarm notification and alarm-removed notification
To set memory thresholds:
1. Enter system view.
system-view
N/A
2. Set free-memory
thresholds.
memory-threshold [ slot slot-number
[ cpu cpu-number ] ] minor minor-value
severe severe-value critical
critical-value normal normal-value
The defaults are as follows:
• Minor alarm threshold—96 MB.
• Severe alarm threshold—64
MB.
Minor
Critical
Free memory space
Severe
Normal
Minor alarm-removed
Severe alarm-removed
Time
Minor
alarm
Severe alarm
Critical alarm
Critical alarm-removed