Step 7 Enable Smart Link on Switch A.
[SwitchA-smlk-group1] smart-link enable
[SwitchA-smlk-group1] quit
Step 8 Enable the receiving of Flush packets.
# Configure Switch B.
<SwitchB> system-view
[SwitchB] interface xgigabitethernet 0/0/1
[SwitchB-XGigabitEthernet0/0/1] smart-link flush receive control-vlan 10 password
simple 123
[SwitchB-XGigabitEthernet0/0/1] quit
# Configure Switch C.
<SwitchC> system-view
[SwitchC] interface xgigabitethernet 0/0/1
[SwitchC-XGigabitEthernet0/0/1] smart-link flush receive control-vlan 10 password
simple 123
[SwitchC-XGigabitEthernet0/0/1] quit
Step 9 Verify the configuration.
# Run the display smart-link group command to view information about the Smart Link group
on Switch A. If the following information is displayed, it indicates that the configuration is
successful.
l The Smart Link function is enabled.
l The control VLAN ID is 10.
l XGE 0/0/1 is the master interface and is in Active state, and XGE 0/0/2 is the slave interface
and is in Inactive state. The load balancing function is configured.
[SwitchA] display smart-link group 1
Smart Link group 1 information :
Smart Link group was enabled
Wtr-time is: 30 sec.
Load-Balance Instance: 10
There is no protected-vlan reference-instance
DeviceID: 0025-9e80-2494 Control-vlan ID:
10
Member Role State Flush Count Last-Flush-Time
----------------------------------------------------------------------
XGigabitEthernet0/0/1 Master Active 1 0000/00/00 00:00:00 UTC+00
:00
XGigabitEthernet0/0/2 Slave Inactive 0 0000/00/00 00:00:00 UTC+00
:00
# Run the shutdown command to shut down XGE 0/0/1, and you can find that XGE 0/0/1 is in
Inactive state and XGE 0/0/2 is in Active state.
[SwitchA] interface xgigabitethernet 0/0/1
[SwitchA-XGigabitEthernet0/0/1] shutdown
[SwitchA-XGigabitEthernet0/0/1] display smart-link group 1
Smart Link group 1 information :
Smart Link group was enabled
Wtr-time is: 30 sec.
Load-Balance Instance: 10
There is no protected-vlan reference-instance
DeviceID: 0025-9e80-2494 Control-vlan ID:
10
Member Role State Flush Count Last-Flush-Time
----------------------------------------------------------------------
XGigabitEthernet0/0/1 Master Inactive 1 0000/00/00 00:00:00 UTC+00
:00
Quidway S6700 Series Ethernet Switches
Configuration Guide - Reliability 2 Smart Link and Monitor Link Configuration
Issue 01 (2011-07-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
39

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S6700 series and is the answer not in the manual?

Huawei Quidway S6700 series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S6700 series
CategoryNetwork Router
LanguageEnglish

Related product manuals