3.5.1 Clearing RRPP Running Information
You can run the reset command to reset the RRPP statistics before recollecting RRPP statistics.
Context
CAUTION
RRPP statistics cannot be restored once cleared. Therefore, confirm the action before you use
the command.
To clear the RRPP statistics, run the following reset command in the user view:
Procedure
Step 1 Run the reset rrpp statistics domain domain-id [ ring ring-id ] command to clear the statistics
of RRPP.
----End
3.5.2 Debugging RRPP
Debugging information facilitates fault location. RRPP debugging includes event debugging
and packet debugging.
Context
CAUTION
Debugging affects the performance of the system. Therefore, after debugging, run the undo
debugging all command to disable it immediately.
When there is an RRPP running fault, run the following debugging command in the user view
to view the debugging information. The debugging information helps to locate and analyze the
fault.
Procedure
Step 1 Run the debugging rrpp [ domain domain-id [ ring ring-id ] ] { error | event | packet | all }
command in the user view to debug RRPP.
----End
3.6 Configuration Examples
This section provides several configuration examples of RRPP.
Quidway S6700 Series Ethernet Switches
Configuration Guide - Reliability 3 RRPP Configuration
Issue 01 (2011-07-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
73

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S6700 series and is the answer not in the manual?

Huawei Quidway S6700 series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S6700 series
CategoryNetwork Router
LanguageEnglish

Related product manuals