12 Patch Management
Quidway NetEngine80
Configuration Guide - Basic Configurations
12-4 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 04 (2009-12-20)
Configuration Procedures
No. Procedure
1 Checking the Running of Patch on the MPU
2 Checking the Running of Patch on the LPU
12.2.2 Checking the Running of Patch on the MPU
Do as follows on the to be upgraded:
Step 1 Run:
display patch-information
The running of patch on the master MPU is checked.
Step 2 Run:
display patch-information history slave
The running of patch on the slave MPU is checked.
----End
Before installing a patch on the MPU, you need to check the running of patch on the master
and slave MPU s. For example:
<Quidway> display patch-information
Service pack Version: V300R005C01SPH007
Pack file name : hd:/v300r005c01sph007.pat
----------The patch information of slot 5----------
Total Patch Unit : 1
Running Patch Unit : 1 - 1
Active Patch Unit : no patch
Deactive Patch Unit : no patch
----------The patch information of slot 9----------
Total Patch Unit : 1
Running Patch Unit : 1 - 1
Active Patch Unit : no patch
Deactive Patch Unit : no patch
----------The patch information of slot 10----------
Total Patch Unit : 1
Running Patch Unit : 1 - 1
Active Patch Unit : no patch
Deactive Patch Unit : no patch
The value of the bolded part in the preceding output is 0. This indicates that no patch runs in
the current system.