151
15) Reading of individual zone boundary on negative side [1044h]
PLC Output (Address n is the input and output top address for MCON Gateway Unit.)
Note If the writing is finished in normal condition, the same content as the demand
command is returned to the response command. If an error is generated, an error
response is returned. [Refer to this Section 22).]
Bit
Address
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
n+2
Demand
Command
[1044h]
0 0 0 1 0 0 0 0 0 1 0 0 0 1 1 0
n+3
Data 0
[Position No.]
–
–
–
–
–
–
–
–
128
64
32
16
8
4
2
1
n+4
Data 1
[0]
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
n+5
Data 2
[0]
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Reading of individual zone boundary on negative side
n+6
Data 3
[Axis No.]
–
–
–
–
–
–
–
–
–
–
–
–
–
4
2
1
PLC Input (Address n is the input and output top address for MCON Gateway Unit.)
Bit
Address b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
n+2
Response
Command
[1044h]
0 0 0 1 0 0 0 0 0 1 0 0 0 0 1 0
n+3
Data 0
[Position No.]
–
–
–
–
–
–
–
–
128
64
32
16
8
4
2
1
n+4
Data 1
[
Individual zone
boundary on
negative side
(Lower word)]
n+5
Data 2
[
Individual zone
boundary on
negative side
(Upper word)]
Reading of individual zone boundary on negative side
n+6
Data 3
[Axis No.]
–
–
–
–
–
–
–
–
–
–
–
–
–
4
2
1
1 word=16 bit
1 word=16 bit
3.4 Fieldbus Type Address Map