241
3) GW-Param 3
Driver Time after Shutdown Release : Set the latency (interval) for when supplying the
power to the driver boards on Slot 0 to 3 in turns.
It is used in purpose to reduce the in-rush
current by making the timing different for power
supply to the driver boards when two or more
driver boards are mounted.
Do not attempt to turn on and off the MP
individually by using the drive cutoff connectors
when this time is to be set as it can be a cause of
alarm generation.
4) GW mode Select
Enable SW : Select whether to activate/inactivate the enable switch
in TP.
BYTE swap : Set the byte swap. [Refer to 4)-1 in this section.]
WORD swap in D-WORD Data : Set whether to swap the W-word sized data with word
size. [Refer to 4)-2 in this section.]
Enable SW in AUTO mode : Select whether to activate/inactivate the enable switch
in AUTO mode.
3.9 About Gateway Parameter Setting Tool