[74] Selecting Automatic Current Reduction Feature (Parameter No.182)
No. Name Symbol Unit Input Range
Default factory
setting
182 Auto Current Adj. Select ACDS -
0: Disabled
1: Enabled
0
It is a feature to make a stop by having the current flow considering the external force influence
when performing the complete stop in positioning.
It will be able to save the power consumption when the transported load is small.
[Refer to 6.2 Selecting Automatic Current Reduction Feature]