Error codes and messages 9-19
72 CMOS Checksum Error Load the Setup default settings and reboot the system.
102 I/O Parity Error Load the Setup defaults and reboot the system.
103 Press <Esc> to turn off NMI or other
key to reboot
1.Press Esc to turn off Non-Maskable Interrupt (NMI) and
proceed to boot the system.
2.Press any other key to reboot the system.
104 Insert system diskette and press
<Enter> to reboot
1.Insert a system diskette into drive A and press Enter to reboot
the system.
2.If the system works when you boot from drive A, your hard disk
may have a problem.
3.Make sure that your hard disk drive is properly installed. Check
all cable connections.
120 I/O Resource Conflict(s) Enter Setup and set the Reset Resource Assignments to Yes, then
reboot the system.
121 Memory Resource Conflict(s) Enter Setup and set the Reset Resource Assignments to Yes, then
reboot the system.
122 IRQ Setting Error 1.Enter Setup and set the Reset Resource Assignments to Yes,
then reboot the system.
2.If the error message reappears, determine which onboard
device is least necessary and disable it under the Devices and I/
O Ports menu in Setup.
123 Expansion ROM Allocation Failed Enter Setup and set the Reset Resource Assignments to Yes, then
reboot the system.
Table 4: Error codes and messages (Continued)
Error codes Error messages Corrective actions
Note:
If any of the errors persist after performing the listed corrective actions, see “Chapter 2: HelpWare support and services” on
page 2-1 for information on obtaining service.
v65xahb.book : chap-9.fm Page 19 Friday, January 16, 1998 4:27 PM