7
OTHER FUNCTIONS
7-51
NXDN RX Status data
Command: 20 0B01, 20 0B02
Data Function Description
bit7 0 (Fixed)
bit6 0/1 (Reserved)
bit5 0/1 NXDN mode When the received NXDN signal is "Narrow," “1” is returned.
bit4 0/1 Receive status While receiving an NXDN signal, “1” is returned. (Regardless of
RAN)
bit3 0/1 Last call finisher When the last call was finished by a user, “1” is returned.
bit2 0/1 Receiving a signal When the audio tone can be heard, “1” is returned.
bit1 0/1 Interfere detection While under an interference (Mode icon NXDN-
vn/n and FM
alternately blink), “1” is returned.
bit0 0/1
Encryption When the call is
encrypted
, “1” is returned.
DCR RX Status data
Command: 20 0D01, 20 0D02
Data Function Description
bit7 0 (Fixed)
bit6 0/1 (Reserved)
bit5 0/1 (Reserved)
bit4 0/1 Receive status While receiving a DCR signal, “1” is returned. (Regardless of UC)
bit3 0/1 Last call finisher When the last call was finished by a user, “1” is returned.
bit2 0/1 Receiving a signal When the audio tone can be heard, “1” is returned.
bit1 0/1 Interfere detection While under an interference (Mode icon DCR and FM alternately
blink), “1” is returned.
bit0 0/1
Encryption When the call is
encrypted
, “1” is returned.
CI-V information
D Commands (Continued)
D-STAR RX data (transceive)
Command: 22 0101
q ~ #0
• • • • • • • • • • • • • • • • • • • • • • • •
X XX X
q ~ #0:Rx data (Up to 30 Bytes)
L “FA” to “FF” are entered after converted to “FF 0A” to “FF 0F” automatically. In this case,
the data length can be up to 60 Bytes.