IDEC SmartRelay functions
IDEC SmartRelay Manual 127
Example of analog values
A sample application is found in the description of the
”Analog comparator” SF on Page 177.
For further information on analog inputs, refer to Chapter
4.1.
Process
variable
Voltage
(V)
Internal
value
Gain Offset
Value shown
(Ax)
-30C
0C
+70C
0
3
10
0
300
1000
0.1
0.1
0.1
-30
-30
-30
-30
0
70
1000 mbar
3700 mbar
5000 mbar
0
6.75
10
0
675
1000
4
4
4
1000
1000
1000
1000
3700
5000
0
5
10
0
500
1000
0.01
0.01
0.01
0
0
0
0
5
10
0
5
10
0
500
1000
1
1
1
0
0
0
0
500
1000
0
5
10
0
500
1000
10
10
10
0
0
0
0
5000
10000
0
5
10
0
500
1000
0.01
0.01
0.01
5
5
5
5
10
15
0
5
10
0
50
0
1000
1
1
1
500
500
500
500
1000
1500
0
5
10
0
50
0
1000
1
1
1
-200
-200
-200
-200
300
800
0
10
0
1000
10
10
-10000
-10000
-10000
0
0.02
0.02
0.02
0.02
2
2
2
2
0.01
0.1
1
10
0
0
0
0
0
0
2
20
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com