Parameter Groups
114
Description
F1-30
Encoder wiring flag
Address:
0xF11E
Min.:
0
Unit:
Max.: 11 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Ones (position): AB signal direction or rotational direction
0: Forward
1: Reverse
Tens (position): Reserved
Description
F1-31
Encoder zero position angle
Address:
0xF11F
Min.:
0
Unit: °
Max.: 359.9 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0.0° to 359.9°
Description
F1-32
Motor gear ratio numerator
Address:
0xF120
Min.:
1
Unit:
Max.: 65535 Data type: UInt16
Default:
1
Change:
At stop
Value Range:
1 to 65535
Description
F1-33
Motor gear ratio denominator
Address:
0xF121
Min.:
1
Unit:
Max.: 65535 Data type: UInt16
Default:
1
Change:
At stop