Parameter Groups
‑106‑
F0-28
Auxiliary frequency coefficient
Address:
0xF01C
Min.:
0
Unit:
%
Max.: 100 Data type: UInt16
Default:
10
Change: In real time
Value Range:
0.00% to 100.00%
Description
This parameter defines the auxiliary frequency reference coefficient when the
frequency superposition mode is Main x Auxiliary. The value 100.00% corresponds
to the target auxiliary frequency reference.
2.2 F1 Parameters of Motor 1
F1-00
Motor type selection
Address:
0xF100
Min.:
0
Unit:
‑
Max.: 2 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Common asynchronous motor
1: Variable frequency asynchronous motor
2: Synchronous motor
Description
A variable frequency motor can adjust its frequency and speed according to the
load. Where the voltage is low, it can reduce the frequency and start reliably.
Where the load is light, it can reduce the frequency, speed, and current to save
electric energy.
A common asynchronous motor is suitable for applications with normal voltage
but often full load. It is designed based on constant frequency and constant
voltage. Therefore, it may not meet all the frequency and speed change
requirements.
F1-01
Rated motor power
Address:
0xF101
Min.:
0.1
Unit:
kW
Max.: 1000 Data type: UInt16
Default:
1.5
Change:
At stop
Value Range:
0.1kW to 1000.0kW