Function Application
‑613‑
Figure 3‑64 Switchover of acceleration/deceleration time
This function is active when the DI is not allocated with function 16 (acceleration/
deceleration time selection terminal 1) or 17 (acceleration/deceleration time
selection terminal 2).
Parameters
Para. Parameter Name
Default Value Range
Description
F8‑25
Switchover
frequency of
acceleration
time 1 and
acceleration
time 2
0.00Hz
0 to the
maximum
frequency
(F0‑10)
This function is used to switch
the acceleration/deceleration
time based on the running
frequency range when the AC
drive is running. This function is
active when the DI is not
allocated with function 16
(acceleration/deceleration time
selection terminal 1) or 17
(acceleration/deceleration time
selection terminal 2).
The valid range is from 0.00 Hz to
the maximum frequency (F0‑10).
F8‑26
Switchover
frequency of
deceleration
time 1 and
deceleration
time 2
0.00Hz
0 to the
maximum
frequency
(F0‑10)
3.5.2.7 Detection Value for Frequency Reach
The DO terminal outputs the active signal when the running frequency of the AC drive
is within the range of the detection value for frequency reach plus or minus the
detection width for frequency reach.