Parameter Groups
‑435‑
0: Disabled
1: Enabled
Description
When the tension setup at pre‑speed function is enabled, you can also enable the
initial roll diameter auto‑tuning function for the AC drive to automatically tune
the initial roll diameter. This function is applicable to rod control only. This
function is enabled when B1‑37 is set to 1, and disabled when B1‑37 is set to 0.
B1-38
Rod length
Address:
0xB126
Min.:
1
Unit:
mm
Max.: 65535 Data type: UInt16
Default:
300
Change:
At stop
Value Range:
1mm to 65535mm
Description
Rod length after the initial roll diameter is auto‑tuned.
B1-39
Rod angle
Address:
0xB127
Min.:
0.1
Unit: °
Max.: 360 Data type: UInt16
Default:
40
Change:
At stop
Value Range:
0.1° to 360.0°
Description
Rod angle after the initial roll diameter is auto‑tuned.
2.26 B2 Taper
B2-00 Taper curve
Address:
0xB200
Min.:
0
Unit:
Max.: 1 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Curve taper
1: Multi‑liner taper
Description
Used to select the taper curve generation mode.