Parameter Groups
434
B1-33
Tension establishment frequency
Address:
0xB121
Min.:
0
Unit:
Hz
Max.: F0‑10 Data type: UInt16
Default:
0.1
Change: In real time
Value Range:
0.00 Hz to value of F0‑10
Description
Used to set the running frequency in scenarios where the tension setup at pre‑
speed function is enabled but the system is not in the tension setup dead zone.
B1-34
Terminal torque boost proportion
Address:
0xB122
Min.:
0
Unit:
%
Max.: 500 Data type: UInt16
Default:
50
Change: In real time
Value Range:
0.0% to 500.0%
Description
When the DI terminal (assigned with function 61) is activated, the tension torque
is boosted by certain ratio. After the DI terminal is deactivated, the boost part is
canceled gradually.
B1-35
Terminal torque boost cancel time
Address:
0xB123
Min.:
0
Unit:
s
Max.: 50 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0s to 50.0s
Description
When the DI terminal (assigned with function 61) is activated, the tension torque
is boosted by certain ratio. After the DI terminal is deactivated, the boost part is
canceled gradually.