EasyManua.ls Logo

Inovance MD500-PLUS Series - 3.2 Motor Configuration

Inovance MD500-PLUS Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Application
‑531‑
3.1.3.3 Acceleration/Deceleration Time Setting
Acceleration time is the time that an AC drive needs to accelerate from zero frequency
to the acceleration/deceleration time base frequency (F0‑25). Deceleration time is the
time that an AC drive needs to decelerate from the acceleration/deceleration time
base frequency (F0‑25) to zero frequency.
Figure 3‑35 Acceleration/deceleration time
The AC drive provides four groups of acceleration/deceleration time, which can be
selected by using DI terminal functions 16 and 17. The four groups of time is set
through the following parameters:
Group 1: F0‑17 and F0‑18
Group 2: F8‑03 and F8‑04
Group 3: F8‑05 and F8‑06
Group 4: F8‑07 and F8‑08
Example
In the following example, DI7 and DI8 are used to switch among different groups of
acceleration/deceleration time.
1. Set F4‑06 and F4‑07 to use DI7 and DI8 for switchover.
Para. No. Name Value
Description
F4‑06 DI7 function 16
Acceleration/Deceleration time selection terminal
1
F4‑07 DI8 function 17
Acceleration/Deceleration time selection terminal
2
2. Set four groups of acceleration/deceleration time parameters to set the
acceleration/deceleration time.

Table of Contents

Other manuals for Inovance MD500-PLUS Series

Related product manuals