Parameter Groups
‑423‑
0: AI1
1: AI2
2: AI3
3: Pulse setting (DI5)
Communication setting (1000H)
5: Communication setting (731AH)
Description
0 to 2: AI channel
3: Pulse
4: Communication address (1000H); set by percentage
5: Communication address (731AH); set by digital with the range from 0 to B0‑05
2.25 B1 Tension Settings
B1-00
Tension reference source
Address:
0xB100
Min.:
0
Unit:
‑
Max.: 5 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: B0‑01 setting
1: AI1 setting
2: AI2 setting
AI3 setting
4: Pulse setting (DI5)
5: Communication setting (1000H)
Description
0: Set by B1‑01
1–5: These channel inputs indicate the percentage of the target tension relative to
the maximum tension, and the maximum tension (B1‑02) must be set correctly
according to the per unit relationship.
B1-01
Tension digital setting
Address:
0xB101
Min.:
0
Unit:
N
Max.: 65000 Data type: UInt16
Default:
50
Change: In real time
Value Range:
0 N to 65000 N