Parameter Groups
424
Description
See channel 0 of B1‑00.
B1-02
Maximum tension
Address:
0xB102
Min.:
0
Unit:
N
Max.: 65000 Data type: UInt16
Default:
500
Change: In real time
Value Range:
0 N to 65000 N
Description
Used to set the maximum tension, corresponding to the tension value when
100.0% is input for channels 1 to 5 of B1‑00. When the actual tension does not
meet requirements, corrections can be performed by editing this parameter
without changing AI, pulse input signals, or curves.
B1-03
Zero-speed threshold
Address:
0xB103
Min.:
0
Unit:
%
Max.: 20 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0% to 20.0%
Description
If the running frequency is lower than the value of this parameter, startup friction
tension compensation will be carried out according to B1‑04. If the running
frequency is higher than the value of this parameter, startup friction tension
compensation will not be carried out.
B1-04
Zero-speed tension rise
Address:
0xB104
Min.:
0
Unit:
%
Max.: 100 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0% to 100.0%
Description
This parameter corresponds to the percentage of tension reference and must be
set properly according to the range of allowable material tension. Set this
parameter to a possible minimal value on the premise of ensuring normal startup.