Function Application
‑663‑
Para.
Function
Default Value Range
Description
Contin
ued
Continued
Contin
ued
Hundreds: E13
0: Coast to
stop
1: Decelerate
to stop
2: Fault reset
4: Warning
5: Canceled
Thousands:
E14
0: Coast to
stop
Ten
thousands:
E15
0: Coast to
stop
1: Decelerate
to stop
3:
Electromagnet
ic shorting
4: Warning
5: Canceled
Continued
3.7.4 Overtemperature Protection
Related parameters
Para.
No.
Function Default
Value Range Description
F9‑57
Motor
overtemperature
protection
threshold
110°C 0°C to 200°C
Used to set the motor overtemperature protection
threshold. When the motor temperature exceeds
the value of F9‑57 (motor overtemperature
protection threshold), the AC drive generates the
motor overtemperature alarm (E45.00) and
responds based on the fault protection action
selection 2 (F9‑48).
F9‑58
Motor
overtemperature
pre‑warning
threshold
90°C 0°C to 200°C
Used to set the motor overtemperature pre‑
warning threshold. When the motor temperature
exceeds the value of F9‑58 (motor overtemperature
pre‑waring threshold), the DO terminal assigned
with function 39 (motor overtemperature) outputs
the active signal.