Parameter Groups
‑107‑
Description
This parameter indicates the power of the motor during normal operation. Its
value is the motor rated voltage multiplied by the motor rated current. Select a
proper motor power on the premise that the motor can meet the requirements of
mechanical load. Factors such as motor heating, allowable overload capacity, and
starting capacity must be considered.
F1-02
Rated motor voltage
Address:
0xF102
Min.:
1
Unit:
V
Max.: 2000 Data type: UInt16
Default:
380
Change:
At stop
Value Range:
1 V to 2000 V
Description
The rated motor voltage indicates the voltage of the motor during normal
operation, which usually refers to the line voltage.
F1-03
Rated motor current
Address:
0xF103
Min.:
0.1
Unit:
A
Max.: 6553.5 Data type: UInt16
Default:
9
Change:
At stop
Value Range:
0.1–6553.5 A
Description
The rated motor current indicates the current of the motor during normal
operation, which usually refers to the line current.
F1-04
Rated motor frequency
Address:
0xF104
Min.:
0.01
Unit:
Hz
Max.: F0‑10 Data type: UInt16
Default:
50
Change:
At stop
Value Range:
0.01 Hz to F0‑10
Description
The rated motor frequency indicates the frequency of the power supply
connected to the stator winding under the rated operation state of the motor.