Parameter Groups
‑154‑
54: Roll diameter reset
When this terminal is active, the initial roll diameter is reset. The initial roll
diameter must be reset when the roll is replaced in the tension mode.
55: Initial roll diameter 1
56: Initial roll diameter 2
In the tension mode, B0‑11/12/13 is selected as the initial roll diameter through
terminal combinations. When these two terminals are inactive, the minimum
winding diameter (B0‑09) is used as the initial roll diameter. When only the
terminal for initial roll diameter 1 selection is active, B0‑11 is used as the initial
roll diameter. When only the terminal for initial roll diameter 2 selection is active,
B0‑12 is used as the initial roll diameter. When these two terminals are active, B0‑
13 is used as the initial roll diameter.
57: Pre‑drive
When the terminal is active, the AC drive switches to the pre‑drive speed control
mode. This function is used to synchronize the linear speed for the axis that
requires automatic reel replacement when the tension mode is used. When the
terminal is deactivated after reel replacement, the tension control can function
properly.
58: Winding/Unwinding switchover
This terminal is used for winding/unwinding switchover in the tension mode.
59: Roll diameter calculation disabled
When this terminal is active, the roll diameter calculation is disabled. In the
tension mode, to avoid influence on the winding diameter calculation for
automatic roll replacement and pre‑drive, winding diameter calculation can be
disabled.
60: Exit tension mode
This terminal is used to exit the tension control mode.
61: Terminal tension rise
When the terminal is activated, the tension torque is increased by certain ratio.
After the terminal is deactivated, the boost part will be canceled gradually based
on time.
62: Thickness selection 1
63: Thickness selection 2
In the tension mode, B0‑32/33/34/35 is selected as the material thickness through
terminal combinations. When these two terminals are inactive, B0‑32 is selected
as the material thickness. When only the terminal for thickness selection 1 is
active, B0‑33 is selected as the material thickness. When only the terminal for
thickness selection 2 is active, B0‑34 is selected as the material thickness. When
these two terminals are active, B0‑35 is selected as the material thickness.
64‑89: Reserved
90: Water cooling system fault
When the water cooling system of T13 models encounters a fault, the terminal
receives the signal and the AC drive reports the E64 alarm.