Parameter List
‑20‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
F3‑30 0xF31E Maximum
generating torque
current
10 to 100 20 ‑ At stop "
F3‑30
"
on
page 145
F3‑31 0xF31F Automatic
frequency rise Kp
0–100 50 ‑ In real time "
F3‑31
"
on
page 145
F3‑32 0xF320 Automatic
frequency rise Ki
0–100 50 ‑ In real time "
F3‑32
"
on
page 145
F3‑33 0xF321 Online torque
compensation
gain
80 to 150 100 ‑ At stop "
F3‑33
"
on
page 145
F4‑00 0xF400 DI1 function
selection
0: No function
1: Forward run (FWD)
2: Reverse run (REV)
3: Three‑wire control
4: Forward jog (FJOG)
5: Reverse jog (RJOG)
6:Terminal (UP)
7:Terminal (DOWN)
8: Coast to stop
9: Fault reset (RESET)
10: Running pause
1 ‑ At stop "
F4‑00
"
on
page 146
Contin
ued
Contin
ued
Continued 11: NO input of external fault
12: Multi‑reference terminal 1
13: Multi‑reference terminal 2
14: Multi‑reference terminal 3
15: Multi‑reference terminal 4
16: Terminal 1 for
acceleration/deceleration
selection
17: Terminal 2 for
acceleration/deceleration
selection
18: Frequency source
switchover
19: UP and DOWN setting clear
(terminal, operating panel)
Contin
ued
Contin
ued
Continued Continued
Contin
ued
Contin
ued
Continued 20: Command source
switchover terminal
21: Acceleration/Deceleration
inhibited
22: PID pause
23: PLC state reset
24: Wobble pause
25: Counter input (DI5)
26: Counter reset
27: Length count input (DI5)
28: Length reset
Contin
ued
Contin
ued
Continued Continued