Parameter Groups
262
F9-56 Motor temperature sensor type
Address:
0xF938
Min.:
0
Unit:
Max.: 4 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0: No sensor (AI3 input)
1: PT100
2: PT1000
3:KTY84
4:PTC130
Description
AI3 can be used to for input of the motor temperature sensor. Four sensors,
including PT100, PT1000, PTC130, and KTY84 are supported. The sensor is
connected to the AI3 and GND terminals. To use the sensor, set the sensor type
correctly. The motor temperature is displayed by U0‑34.
F9-57
Motor overtemperature protection threshold
Address:
0xF939
Min.:
0
Unit: °C
Max.: 200 Data type: UInt16
Default:
110
Change: In real time
Value Range:
0°C to 200°C
Description
Used to set the motor overtemperature protection threshold. When the motor
temperature exceeds the value of F9‑57 (Motor overheat protection threshold),
the AC drive reports a motor overheat fault (Err45) and acts as selected by F9‑48.
F9-58
Motor overtemperature pre-warning threshold
Address:
0xF93A
Min.:
0
Unit: °C
Max.: 200 Data type: UInt16
Default:
90
Change: In real time
Value Range:
0°C to 200°C
Description
Used to set the motor overtemperature pre‑warning threshold. When the motor
temperature exceeds the value of F9‑58 (Motor overheat pre‑waring threshold),
the DO allocated with function 39 (Motor overheat) outputs an active signal.