Parameter Groups
‑325‑
Default:
0
Change: In real time
Value Range:
0: A0‑05
1: Frequency source
Description
A0-10
Speed limit offset/Windows frequency
Address:
0xA00A
Min.:
0
Unit:
Hz
Max.: F0‑10 Data type: UInt16
Default:
5
Change: In real time
Value Range:
0.00 Hz to value of F0‑10
Description
A0-11
Effective mode of speed limit offset
Address:
0xA00B
Min.:
0
Unit:
Max.: 2 Data type: UInt16
Default:
1
Change:
At stop
Value Range:
0: Bidirectional offset valid
1: Unidirectional offset valid
2: Windows mode
Description
A0-12
Frequency acceleration time
Address:
0xA00C
Min.:
0
Unit:
s
Max.: 6500 Data type: UInt16
Default:
1
Change: In real time
Value Range:
0.0s to 6500.0s
Description
A0-13
Frequency deceleration time
Address:
0xA00D