Parameter Groups
‑334‑
57: Pre‑drive
When the terminal is active, the AC drive switches to the pre‑drive speed control
mode. This function is used to synchronize the linear speed for the axis that
requires automatic reel replacement when the tension mode is used. When the
terminal is deactivated after reel replacement, the tension control can function
properly.
58: Winding/Unwinding switchover
This terminal is used for winding/unwinding switchover in the tension mode.
59: Roll diameter calculation disabled
When this terminal is active, the roll diameter calculation is disabled. In the
tension mode, if automatic roll replacement and pre‑drive are required, winding
diameter calculation can be disabled to avoid influence on the winding diameter
calculation.
60: Exit tension mode
Used to exit the tension control mode.
61: Terminal tension rise
When the terminal is activated, the tension torque is increased by certain ratio.
After the DI terminal is deactivated, the boost part will be canceled gradually
based on time.
62: Thickness selection 1
63: Thickness selection 2
In the tension mode, B0‑32/33/34/35 is selected as the material thickness through
terminal combinations. When these two terminals are inactive, B0‑32 is selected
as the material thickness. When only the terminal for thickness selection 1 is
active, B0‑33 is selected as the material thickness. When only the terminal for
thickness selection 2 is active, B0‑34 is selected as the initial roll diameter. When
these two terminals are active, B0‑35 is selected as the material thickness.
64‑89: Reserved
90: Water cooling system fault
When the water cooling system of T13 models encounters a fault, the terminal
receives the signal and the AC drive reports the E64 alarm.
91: Low liquid level fault
When the liquid in the water tank of T13 models is too low, the terminal receives
the signal and the AC drive reports the A63 alarm.
92: Revolution count reset
The number of revolutions counted will be cleared after this terminal is activated.
93: Reserved
A1-01
VDI2 function
Address:
0xA101
Min.:
0
Unit:
‑
Max.: 93 Data type: UInt16