Parameter Groups
‑343‑
Ones: VDI1
0: Set by A1‑06
1: DO state
2: DI state
Tens: VDI2
0: Set by A1‑06
1: DO state
2: DI state
Hundreds: VDI3
0: Set by A1‑06
1: DO state
2: DI state
Thousands: VDI4
0: Set by A1‑06
1: DO state
2: DI state
Ten thousands: VDI5
0: Set by A1‑06
1: DO state
2: DI state
Description
The VDI state can be set in two modes, which is selected in A1‑05.
When A1‑05 is set to 0, the VDI state is determined by the state of the VDO and
VDIx is uniquely bound to VDOx (x ranges from 1 to 5).
When A1‑05 is set to 1, the VDI state is determined by the binary bit of A1‑06.
A1-06
VDI state selection
Address:
0xA106
Min.:
0
Unit:
Max.: 11111 Data type: UInt16
Default:
0
Change: In real time
Value Range: