Parameter Groups
‑353‑
A5-04
Fast current limit
Address:
0xA504
Min.:
0
Unit:
‑
Max.: 1 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0: Disabled
1: Enabled
Description
This function is used to minimize the possibility of overcurrent faults, ensuring
normal operation of the AC drive.
Disable this function in hoist applications such as cranes.
A5-05
Sampling delay
Address:
0xA505
Min.:
1
Unit:
‑
Max.: 13 Data type: UInt16
Default:
5
Change: In real time
Value Range:
1 to 13
Description
A5-06
Undervoltage threshold
Address:
0xA506
Min.:
150
Unit:
V
Max.: 700 Data type: UInt16
Default:
350
Change: In real time
Value Range:
150.0V to 700.0V
Description
When the bus voltage is lower than the value set by A5‑06, the AC drive reports
E09.00.
A5-07
SVC optimization selection
Address:
0xA507
Min.:
0
Unit:
‑
Max.: 2 Data type: UInt16
Default:
1
Change:
At stop