Parameter Groups
‑355‑
Value Range:
0100
Description
A5-18
Display parameter address 3
Address:
0xA512
Min.:
0
Unit:
Max.: 100 Data type: UInt16
Default:
2
Change: Unchangeable
Value Range:
0100
Description
A5-19
Display parameter address 4
Address:
0xA513
Min.:
0
Unit:
Max.: 100 Data type: UInt16
Default:
3
Change: Unchangeable
Value Range:
0100
Description
A5-21
Low speed carrier frequency
Address:
0xA515
Min.:
0
Unit:
Max.: 16 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.016.0
Description
This parameter is used to set the carrier frequency of the motor at low speed to
lower the motor noise in the V/f or FVC mode. The carrier frequency is the smaller
one between F0‑15 and A5‑21. When the value of A5‑21 is greater than or equal to
4 kHz, the value of A5‑21 is active. When the value of A5‑21 is lower than 4 kHz, 4
kHz is used.
A5-22
Dead-zone compensation auto-tuning
Address:
0xA516