Parameter Groups
‑362‑
‑100.0% to +100.0%
Description
This parameter defines the zero offset coefficient for AI3 voltage correction.
A6-22
AI disconnection detection threshold
Address:
0xA616
Min.:
0
Unit:
%
Max.: 100 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0% to 100.0%
Description
This parameter indicates the AI disconnection detection threshold. 100%
corresponds to 10 V.
A6-23
AI disconnection detection time
Address:
0xA617
Min.:
0
Unit:
s
Max.: 6553.5 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0s to 6553.5s
Description
This parameter indicates the AI disconnection detection time in the unit of 0.1s.
A6-24
Jump point set through AI1
Address:
0xA618
Min.:
‑100
Unit:
%
Max.: 100 Data type: Int16
Default:
0
Change: In real time
Value Range:
‑100.0% to +100.0%
Description
This parameter defines the jump point set through AI1.
A6-25
Jump amplitude set through AI1
Address:
0xA619
Min.:
0
Unit:
%
Max.: 100 Data type: UInt16
Default:
0.1
Change: In real time
Value Range: