EasyManua.ls Logo

Inovance MD500-PLUS Series - Page 377

Inovance MD500-PLUS Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Groups
376
Description
A9-49
Synchronous motor energy-saving control
Address:
0xA931
Min.:
0
Unit:
Max.: 1 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Disabled
1: Enabled
Description
A9-50
Maximum flux weakening current limit margin
Address:
0xA932
Min.:
200
Unit:
Max.: 1000 Data type: UInt16
Default:
1000
Change:
At stop
Value Range:
200 to 1000
Description
A9-51
Advanced settings for asynchronous motor parameter auto-tuning
Address:
0xA933
Min.:
0
Unit:
Max.: 1111 Data type: UInt16
Default:
111
Change:
At stop
Value Range:
Ones: Rotor resistance and leakage inductance DC offset
0: Standard offset
1: Large offset
Tens: New rotor resistance and leakage inductance auto‑tuning algorithm
0: Disabled
1: Enabled
Hundreds: New mutual inductance static auto‑tuning algorithm
0: Disabled
1: Enabled
Thousands: Stator resistance auto‑tuning algorithm
0: Current open loop
1: Current closed loop

Table of Contents