B6-07
Read gain 2
Address:
0xB607
Min.:
0
Unit:
Max.: 100 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.00100.00
Description
Indicates the read coefficient 2 for communication free mapping.
When this parameter is set to 10.00, the read coefficient will be magnified 10
times.
When this parameter is set to 0.10, the read coefficient will be reduced by 10%.
B6-08
Source address 3
Address:
0xB608
Min.:
0
Unit:
Max.: 0xFFFF Data type: UInt16
Default:
0
Change: In real time
Value Range:
0 to value of 0xFFFF
Description
Indicates the communication free mapping source address 3.
B6-09
Mapping address 3
Address:
0xB609
Min.:
0
Unit:
Max.: 0xFFFF Data type: UInt16
Default:
0
Change: In real time
Value Range:
0 to value of 0xFFFF
Description
Indicates the communication free mapping target address 3.
B6-10
Write gain 3
Address:
0xB60A
Min.:
0
Unit:
Max.: 100 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.00100.00
Description
Indicates the write coefficient 3 for communication free mapping.