EasyManua.ls Logo

Inovance MD500-PLUS Series - Page 451

Inovance MD500-PLUS Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Groups
450
Min.:
0
Unit:
Max.: 0xFFFF Data type: UInt16
Default:
0
Change: In real time
Value Range:
0 to value of 0xFFFF
Description
Indicates the communication free mapping source address 9.
B6-33
Mapping address 9
Address:
0xB621
Min.:
0
Unit:
Max.: 0xFFFF Data type: UInt16
Default:
0
Change: In real time
Value Range:
0 to value of 0xFFFF
Description
Indicates the communication free mapping target address 9.
B6-34
Write gain 9
Address:
0xB622
Min.:
0
Unit:
Max.: 100 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.00100.00
Description
Indicates the write coefficient 9 for communication free mapping.
When this parameter is set to 10.00, the write coefficient will be magnified 10
times.
When this parameter is set to 0.10, the write coefficient will be reduced by 10%.
B6-35
Read gain 9
Address:
0xB623
Min.:
0
Unit:
Max.: 100 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.00100.00
Description
Indicates the read coefficient 9 for communication free mapping.