B6-90
Write gain 23
Address:
0xB65A
Min.:
0
Unit:
‑
Max.: 100 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.00–100.00
Description
Indicates the write coefficient 23 for communication free mapping.
When this parameter is set to 10.00, the write coefficient will be magnified 10
times.
When this parameter is set to 0.10, the write coefficient will be reduced by 10%.
B6-91
Read gain 23
Address:
0xB65B
Min.:
0
Unit:
‑
Max.: 100 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.00–100.00
Description
Indicates the read coefficient 23 for communication free mapping.
When this parameter is set to 10.00, the read coefficient will be magnified 10
times.
When this parameter is set to 0.10, the read coefficient will be reduced by 10%.
B6-92
Source address 24
Address:
0xB65C
Min.:
0
Unit:
‑
Max.: 0xFFFF Data type: UInt16
Default:
0
Change: In real time
Value Range:
0 to value of 0xFFFF
Description
Indicates the communication free mapping source address 24.
B6-93
Mapping address 24
Address:
0xB65D
Min.:
0
Unit:
‑
Max.: 0xFFFF Data type: UInt16
Default:
0
Change: In real time
Value Range: