Function Application
‑583‑
Para.
Function
Default Value Range
Description
A0‑03
Torque digital
setting
100.0% ‑200.0% to
+200.0%
Digital setting in the torque
control mode The torque
reference is a relative value.
The value 100.0%
corresponds to the rated
motor torque. Check U0‑06
to obtain the motor output
torque. The torque value
range is 200.0% to
+200.0%, which means that
the maximum torque of the
AC drive is twice the rated
motor torque.
When the parameter value
is positive, the AC drive runs
in the forward direction.
When the parameter value
is negative, the AC drive
runs in the reverse
direction.
A0‑04
Torque filter time
0.000s 0s to 5.000s
Torque filter time
A0‑05
Speed limit digital
setting
0.0% ‑120.0% to
+120.0%
A0‑07 Torque
acceleration time
1.00s 0.00s to 650.00s
A0‑08 Torque
deceleration time
1.00s 0.00s to 650.00s
A0‑09
Speed limit
reference source
0
0: Set through A0‑
05
1: Frequency
source setting
A0‑10
Speed limit offset
5.00 0 to max.
frequency (F0‑10)
A0‑11
Effective mode of
speed limit offset
1
0: Bidirectional
offset effective
1: Unidirectional
offset effective
2: Window mode
A0‑12 Frequency
acceleration time
1.0s 0.0s to 6500.0s