Function Application
‑632‑
Para. Name De
fault
Value Range
Description
B0‑04
Linear speed
input source
0
0: No input
1: AI1
2: AI2
3: AI3
4: Pulse input
(DI5)
5:
Communica
tion (1000H)
6:
Communica
tion (731AH)
0: No input
1–6: When the linear speed is
input through the preceding
channels, the maximum linear
speed (B0‑05) must be set
according to the per unit
relationship. The 1000H address is
set according to the percentage.
The 731AH address is directly set
by digit, and the digital setting
range is from 0 to B0‑05.
B0‑05
Maximum linear
speed
1000.
0 m/
min
0.0 m/min to
6500.0 m/min
This parameter is used to set the
maximum linear speed.
It corresponds to the actual linear
speed when 100.0% is input for
channels 1 to 5 of B0‑04. This
value may differ from the
maximum linear speed required
by production. Verify them during
settings.
When the linear speed is used to
calculate the winding diameter
(B0‑07 = 0), the larger the
parameter is, the larger the
calculated winding diameter is,
and vice versa. According to this
rule, the parameter can be
corrected according to the
deviation between the calculated
roll diameter and the actual value.
B0‑41
Source of
constant linear
speed
0 0: AI1
1: AI2
2: AI3
3: Pulse
reference (DI5)
4:
Communica
tion (1000H)
5:
Communica
tion (731AH)
0 to 2: AI channel
3: Pulse input
4: Communication address
(1000H); set by percentage
5: Communication address
(731AH); set by digital with the
range from 0 to B0‑05