Function Application
‑651‑
Para.
No.
Name Default
Value Range Description
B2‑11
Linear taper
switchover point 2
200.0 mm B2‑09 to B0‑08
B2‑12
Taper of switchover
point 2
90.0% 0.0% to 100.0%
B2‑13
Linear taper
switchover point 3
250.0 mm B2‑11 to B0‑08
B2‑14
Taper of switchover
point 3
80.0% 0.0% to 100.0%
B2‑15
Linear taper
switchover point 4
300.0 mm B2‑13 to B0‑08
B2‑16
Taper of switchover
point 4
70.0% 0.0% to 100.0%
B2‑17
Linear taper
switchover point 5
400.0 mm B0‑15 to B0‑08
B2‑18
Taper of switchover
point 5
50.0% 0.0% to 100.0%
B2‑19
Taper at maximum
roll diameter
30.0% 0.0% to 100.0%
The following figure shows a multi‑point linear taper curve, where the ordinate
represents the ratio of tension after taper is set to original tension, and the abscissa
represents the roll diameter. You can set the preceding parameters to obtain a multi‑
liner taper curve.
Figure 3‑80 Multi‑point linear taper curve