Function Application
‑686‑
Para.
Function Basic Unit Description
U0‑68
AC drive state
on the
communication
extension card
1 0: Stop; 1: Run
0: Forward run; 1: Reverse run
This parameter indicates whether any fault
occurs to the AC drive.
0: No fault
1: Fault
This parameter indicates whether the running
frequency reaches the frequency reference.
0: The running frequency does not reach the
frequency reference.
1: The running frequency has reached the
frequency reference.
This parameter indicates whether DP
communication is normal.
0: Normal
1: Abnormal
Communication control as the reference
source for the AC drive
Communication control as the command
source for the AC drive
Speed control/torque control
Fault code (main code). See specific fault
description.
U0‑69 Frequency
transmitted to
the
communication
extension card/
0.01 Hz
1
‑
U0‑70
Speed
transmitted to
the
communication
extension card/
RPM
1
‑
U0‑71
Current specific
to the
communication
extension card
(A)
1
‑
U0‑72
Communication
card error state
1
‑
U0‑73 Target torque
before filter
0.1
Target torque not filtered in torque control
mode
U0‑74 Target torque
after filter
0.1%
Target torque filtered in torque control mode