Design and Environmental Specifications Intel® Server Board S2600CW Family TPS
150 Revision 2.4
amount of airflow required for their specific application and environmental conditions. Intel
Corporation cannot be held responsible, if components fail or the server board does not
operate correctly when used outside any of its published operating or non-operating limits.
11.2 MTBF
The following is the calculated Mean Time Between Failures (MTBF) 40°C (ambient air). These
values are derived using a historical failure rate and multiplied by factors for application,
electrical and/or thermal stress and for device maturity. You should view MTBF estimates as
“reference numbers” only.
Calculation Model: Telcordia* Issue 2, method I case 3
Operating Temperature: Server in 40°C ambient air
Operating Environment: Ground Benign, Controlled
Duty Cycle: 100%
Quality Level: II
Table 89. MTBF Estimate
Assembly
Failure Rate
MTBF
Motherboard
4261
234,708