Intel® Server Board S2600CW Platform Management  Intel® Server Board S2600CW Family TPS 
72    Revision 2.4 
Table 10. Processor Sensors 
Processor presence and fault state 
Relative temperature reading by means of PECI 
Processor VRD Over-Temperature 
Indication 
Discrete sensor that indicates a processor VRD has 
crossed an upper operating temperature threshold 
Threshold sensor that indicates a processor  
power-good state 
Processor Thermal Control (Prochot) 
Percentage of time a processor is throttling due to 
thermal conditions 
 
5.3.11.1  Processor Status Sensors 
The BMC provides an IPMI sensor of type processor for monitoring status information for each 
processor slot. If an event state (sensor offset) has been asserted, it remains asserted until one 
of the following happens: 
1.  A Rearm Sensor Events command is executed for the processor status sensor. 
2.  An AC or DC power cycle, system reset, or system boot occurs. 
The BMC provides system status indication to the front panel LEDs for processor fault 
conditions shown in Table 11. 
CPU Presence status is not saved across AC power cycles and therefore will not generate a 
de-assertion after cycling AC power. 
Table 11. Processor Status Sensor Implementation 
FRB2/Hang in POST failure 
FRB3/Processor startup/initialization failure (CPU fails to start) 
Configuration error (for DMI) 
SM BIOS uncorrectable CPU-complex error 
Processor presence detected 
Terminator presence detected 
Note:  
1.  Fault is not reflected in the processor status sensor.