Intel® Server Board S2600CW Family TPS Intel® Server Board S2600CW Jumper Blocks
Revision 2.4
111
8. Intel
®
Server Board S2600CW Jumper Blocks
The server boards have several 3-pin jumper blocks that you can use to configure, protect, or
recover specific features of the server boards.
The following symbol identifies Pin 1 on each jumper block on the silkscreen:
Figure 21. Jumper Blocks
Table 37. Server Board Jumpers
Jumper Name
Pins
System Results
BIOS Recovery
1-2
Pins 1-2 should be connected for normal system operation. (Default)
2-3
The main system BIOS does not boot with pins 2-3 connected. The system only boots
from EFI-bootable recovery media with a recovery BIOS image present.
BIOS Default
(that is, CMOS
Clear)
1-2
These pins should have a jumper in place for normal system operation. (Default)
2-3
If pins 2-3 are connected when AC power unplugged, the CMOS settings clear in 5
seconds. Pins 2-3 should not be connected for normal system operation.
ME Force
Update
1-2
ME Firmware Force Update Mode Disabled (Default)
2-3
ME Firmware Force Update Mode Enabled