Intel® Server Board S2600CW Family TPS  Intel® Server Board S2600CW Platform Management 
Revision 2.4     
  Energy Star Server Support. 
  Smart Ride Through (SmaRT) / Closed Loop System Throttling (CLST). 
  Power Supply Cold Redundancy. 
  Power Supply FW Update. 
  Power Supply Compatibility Check. 
  BMC FW reliability enhancements: 
-  Redundant BMC boot blocks to avoid possibility of a corrupted boot block 
resulting in a scenario that prevents a user from updating the BMC 
-  BMC System Management Health Monitoring 
5.2  Platform Management Features and Functions 
5.2.1  Power Subsystem 
The server board supports several power control sources which can initiate power-up or 
power-down activity. 
External Signal Name or  
Internal Subsystem 
Turns power off, or power cycle 
Commands 
Routed through command processor 
Turns power on or off, or power cycle 
Implemented by means of BMC 
internal logic 
Turns power on when AC power returns 
Sleep S4/S5 signal (same as 
POWER_ON) 
 
5.2.2  Advanced Configuration and Power Interface (ACPI) 
The server board has support for the following ACPI states. 
Table 9. ACPI Power States 
  The front panel power LED is on (not controlled by the BMC). 
  The fans spin at the normal speed, as determined by sensor inputs. 
  Front panel buttons work normally.