Intel® Server Board S2600CW Platform Management  Intel® Server Board S2600CW Family TPS 
62    Revision 2.4 
  Power unit management: Support for power unit sensor. The BMC handles 
power-good dropout conditions. 
  DIMM temperature monitoring: New sensors and improved acoustic management 
using closed-loop fan control algorithm taking into account DIMM temperature 
readings. 
  Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported 
on embedded NICs). 
  Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported on 
embedded NICs). 
  Platform environment control interface (PECI) thermal management support. 
  Email alerting. 
  Support for embedded web server UI in Basic Manageability feature set. 
  Enhancements to embedded web server. 
-  Human-readable SEL 
-  Additional system configurability 
-  Additional system monitoring capability 
-  Enhanced online help 
  Integrated KVM. 
  Enhancements to KVM redirection. 
-  Support for higher resolution 
  Integrated Remote Media Redirection. 
  Lightweight Directory Access Protocol (LDAP) support. 
  Intel
®
 Intelligent Power Node Manager support. 
  Embedded platform debug feature which allows capture of detailed data for later 
analysis. 
  Provisioning and inventory enhancements: 
-  Inventory data/system information export (partial SMBIOS table) 
  DCMI 1.5 compliance (product-specific). 
  Management support for PMBus* rev1.2 compliant power supplies. 
  BMC Data Repository (Managed Data Region Feature). 
  Support for an Intel
®
 Local Control Display Panel. 
  System Airflow Monitoring. 
  Exit Air Temperature Monitoring. 
  Ethernet Controller Thermal Monitoring. 
  Global Aggregate Temperature Margin Sensor. 
  Memory Thermal Management. 
  Power Supply Fan Sensors.